Skip to main content
PT GLEH

Facility

The Blang Bintang incinerator, Aceh Besar.

A Government of Aceh–owned facility operated by PT GLEH. One two-chamber incinerator, a refrigerated B3 store and a weighbridge on a 2,780 m² site.

Status
Commissioning early Nov 2026
Arrangement
Leased by GLEH from the Government of Aceh as Aceh regional property for 5 years (2026–2031), approved by the Governor of Aceh under an annual payment scheme (September 2026).
Facility permits
The facility holds a Technical Approval, an SLO (certificate of operational worthiness) and environmental approval (DELH) in the name of the asset owner, UPTD Balai Penanganan Sampah, DLHK Aceh. See document numbers
Blang Bintang incinerator building with its stack, weighbridge and landscaped grounds
Blang Bintang facility, Aceh Besar · 2026

Specifications

Figures from the technical documents.

Specifications follow the facility’s Technical Approval and SLO. Operational readiness is verified during commissioning, November 2026.

Maximum capacity
300 kg/jam
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Primary chamber
5,7 m³ · 800–1.000 °C
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Secondary chamber
3,2 m³ · 1.000–1.200 °C
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Main stack
30 m · Ø 0,8 m
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Emergency stack
18 m
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Refrigerated B3 storage
≤ 0 °C · 16,875 m³
KLHK Technical Approval S.482/2022 & SLO S.179/2024
Site area
2.780 m²
2026 regional-property lease documents
Incinerator & B3 storage building
668,94 m²
2026 regional-property lease documents

Process schematic

Two chambers, one stack.

Incineration flow schematic (vertical)01ReceivingManifest · weigh02B3 storage≤ 0 °C · 16.875 m³03Chamber 15.7 m³ · 800–1,000 °C04Chamber 23.2 m³ · 1,000–1,200 °C05Emission controlCyclone · scrubber06Stack 30 mØ 0.8 m · emergency 18 mfly ashA347-1Data: Tech. Approval S.482/2022 · SLO S.179/2024

Accepted waste

Five waste codes from healthcare facilities.

List per the facility SLO. Waste outside these codes is not accepted.

  • A337-1Clinical (infectious) waste
  • A337-2Expired or unused pharmaceutical products
  • A337-4Medical equipment
  • B337-1Pharmaceutical packaging
  • B337-2Healthcare wastewater sludge
  • A347-1 · A347-2 · B347-1 · B110dFly ash, bottom ash, flue-gas treatment residue and used rags go to a licensed B3 waste handler.

Source: KLHK Technical Approval S.482/2022 & SLO S.179/2024

Documentation

Site photos, as they are.

Photos taken on site. Editing limited to colour and cropping. Areas not yet documented are marked.

Weighbridge at the Blang Bintang facility gate
Weighbridge, Blang Bintang · 2026
Blower, ducting and cyclone inside the incinerator building
Emission control unit, Blang Bintang · 20 June 2026

Location

Jl. Radar Km 08, Data Makmur, Blang Bintang.

Within the Blang Bintang Regional Landfill area, Aceh Besar. The head office is in Lambhuk, Banda Aceh.

Guide for hospitals
Map of Aceh: Banda Aceh head office, Blang Bintang facility (commissioning early November 2026) and the planned Lhokseumawe site100 km200 kmBANDA ACEHMEULABOHTAKENGONLANGSATAPAKTUANKUTACANEBlang BintangCOMMISSIONING EARLY NOV 2026LhokseumawePLANNEDINDIAN OCEANMALACCA STRAITN100 km
Boundary simplified from the BAKOSURTANAL 1:250,000 base map. The 100/200 km rings around Blang Bintang are indicative, not service limits.

Waste data

Medical waste by district, 2024.

Monthly reports from 35 hospitals in 22 districts, compiled. These figures underpin pickup-route planning to Blang Bintang.

District · Reporting hospitals · Tonnes, 2024
DistrictTonnes, 2024Tonnes, 2024
Banda Aceh469.7
Bireuen88.0
Pidie87.9
Langsa73.7
Aceh Tengah68.8
Aceh Barat Daya64.3
Aceh Tamiang63.2
Nagan Raya53.4
Aceh Selatan52.8
Aceh Timur48.8
Aceh Barat41.6
Aceh Utara39.6
Pidie Jaya31.8
Bener Meriah25.5
Simeulue21.3
Aceh Singkil20.2
Aceh Besar16.9
Aceh Jaya15.4
Subulussalam15.3
Gayo Lues12.1
Aceh Tenggara8.5
Sabang6.1
Total1,324.8

Banda Aceh is dominated by RSUD dr. Zainoel Abidin (±395 t). Districts without a report, such as Lhokseumawe, are not listed.

Source: 2024 monthly hospital B3 waste generation reports, compiled by district

For hospitals

Waste codes, packaging, pickup schedule and quotes on one page.

  • Electronic manifest (Festronik)
  • Certificate of Destruction
  • Licensed B3 waste transporters
Open the hospital guide

Visualisation of the Blang Bintang facility (not a documentary photo)